Let us first talk about the principle of analog monitoring: simply by the camera (front-end) through the transmission device to the back-end storage (DVR or monitoring host) for video and real-time preview. Therefore, we can start from these parts.
Elevator simulation wireless monitoring necessary tools: screwdriver, pliers, multimeter, measuring instrument, engineering treasure and so on.
First, check whether the back-end video capture card or hard disk recorder has loose interfaces and whether the power supply is normal. If everything is normal, you need to go to the front end to check if the camera power and the camera are working properly.
Surveillance cameras have no video signal. First check if there is any problem with the power supply of the camera. Use a multimeter to check whether the 12V output voltage is normal. If it is normal, continue troubleshooting other fault points. If it is not normal, replace the 12V power supply and do another test.
After checking the camera power problem, and then detect whether the camera is faulty, you can use the engineering treasure to directly detect whether the camera has an image. If there is no image, the camera is proved to be faulty. If the image is normal, the camera is proved to be normal, and then the test is used to connect. The line is normal.
Monitoring faults is a relatively tedious project. There are many causes of no image faults. You should check them one by one. You must be careful in the troubleshooting process. Otherwise, the root cause of the fault may not be found.
240 M3/h Concrete Batching Plants
During the maintenance of the mixing station, the main power supply must be cut off, the door of the distribution cabinet must be locked, and the key should be kept by the electrician.Power cutting and transmission must be operated by electrician.When starting the belt conveyor, mixing host, and other motors, it is necessary to observe whether there are people or other sundry things on the motor, in order to prevent injury or damage to the equipment when starting. When cleaning, it is strictly prohibited to flush the electric motor, electrical switch, solenoid valve and other electrical appliances with water to prevent electric shock and damage to electrical equipment.When the mixer is working, it is forbidden to stand in the discharging area.Non-operators are forbidden to enter the control room, smoking and doing things unrelated to the operation are prohibited.There is no operator in the operating room. Power must be cut off and doors and Windows must be locked before leaving.