Water heating system consists of four parts

Water heating is currently a popular heating method, so many people will choose to install water heating when carrying out home renovations. What constitutes a complete water heating system?

A complete water heating system consists of four parts:

1. The boiler heating furnace can be said to be the heart of the entire heating system. Whether it can operate efficiently and stably directly depends on whether the floor heating system can continue to provide effective heating.

Role: Most boilers can set their own heating time, calculated by the household. Some brands can also provide domestic hot water. Advanced, energy-saving, and safer than traditional heating, it can be installed on the wall or in the corner of the room. The price is more than a few thousand yuan to about ten thousand yuan.



2. The ground part of the ground is usually composed of insulation layer, reflective film, heating pipe, backfill layer and so on. The insulation layer is usually 50px EPS or XPS material; the reflective film is mostly aluminum emission film; the heating pipe is mainly PEX pipe, followed by the PE-RT and PB pipe.

Role: The cost of the insulation material does not account for the bulk of the overall floor heating system budget, but it does allow the entire floor heating system to operate stably. It also allows the heat to be concentrated and distributed in suitable places, minimizing heat loss. A complete heating system must be a good pipe, and the heat must pass through the floor heating pipe to all rooms that need to be heated.

3. The water collector is a water flow distribution and gathering device composed of a water separator and a water collector. Usually in the ground heating area, it is necessary to divide a large area into small pieces for control, or for a room with multiple functions in a house, which needs to be separately controlled. At the same time, the floor heating system is controlled by the hydraulic characteristics and the floor heating coil is limited to a certain length. This requires that the same floor heating area or heating rooms in the same house be divided into multiple loops, and each loop must be shut down and flow adjusted.

Function: Floor heating system is the end of buried heating, most of its structure is buried under the floor, only the water collector leaks out, it is very important as a key component of floor heating control. On the one hand, it distributes the flow of water in the main heating pipe as required to ensure that the flow of the branch circuit in each area meets the heating load requirements. At the same time, the flow of each branch circuit must be collected and input into the backwater main pipe to realize the circulation operation. . On the other hand, because each functional area (room) needs heating according to demand, in order to facilitate the adjustment of the valves controlling the water separator and the branch circuit of the water collector, the valve assumes the tasks of flow distribution and adjustment.



4. The thermostat thermostat is a must-have accessory for the boiler, it is an integrated programmer and software and realizes the intelligent control of the temperature switch, can freely adjust the indoor temperature, and can set the switches of various time periods according to the user's requirements. Automatically adjust the room temperature in various pre-set modes to achieve a comfortable temperature.

Role: Most floor heating controllers are smart thermostats. The room heating system is equipped with a thermostat, especially an intelligent thermostat, which is an extremely important and most important link in the comprehensive system of energy-saving heating.

Water heating is an indoor heating method that many people choose. It is also the most comfortable heating method. It is safe and environmentally friendly, and it is also good for the body. It is also a symbol of quality of life. In order to live a warm winter, when everyone renovates the house, Don't forget this one.

Shanghai Shure Environmental Technology Co., Ltd. Tel

Anti-wear Ring

Installation and precautions of track connecting rod oil seal
The installation steps for the track link oil seal are as follows:
1. Cleaning: Clean the connecting parts to ensure that the surface is flat, clean, and free of grease and dirt.
2. Oil application: Apply a layer of lubricating oil to the connecting parts for better installation.
3. Installation: Gently push the oil seal into the connection area to ensure that the lip of the oil seal is not damaged.
4. Positioning: After positioning the oil seal, press it with your fingers to ensure it is in the correct position.
5. Inspection: Check if the oil seal is installed correctly and ensure that the lip is not damaged.
The precautions are as follows:
Before installation, check if the oil seal is damaged. If the oil seal is damaged, replace it with a new one.
Before installation, ensure that the surface of the connecting parts is flat, clean, and free of grease and dirt.
3. When installing the oil seal, gently push in to avoid damaging the lip of the oil seal.
4. After installation, check whether the oil seal is installed correctly to ensure that the lip is not damaged.
5. During use, the condition of the oil seal should be regularly checked. If any damage or wear is found, the oil seal should be replaced in a timely manner.

Wear ring for excavator,For excavator track,For excavator accessories

Safe Seal Technology Co., Ltd. , https://www.aprseal.com

This entry was posted in on