ZBSF series stainless steel solenoid valve introduction and related troubleshooting

First, use: ZBSF series stainless steel solenoid valve is the industrial process automation control system with the actuator. He can automatically turn on and off after receiving the electronic control signal to realize the on-off or flow control and regulation of the medium in the pipeline. Our electromagnetic valve is widely used in printing, textile, plastics, chemicals, rubber, pharmaceutical and other industries and departments, bathrooms, canteens, air conditioners and other daily life facilities. ZBSF-Y-type solenoid valve main advantage is corrosion-resistant, high temperature, so most for the corrosive liquids, gases and so on. Second, the model description: ZBSF- () behind the brackets can be associated with the letters mean different meaning, ZBSF-K on behalf of the normally open is not normally closed, ZBSF-B means explosion-proof without the general type, ZBSF-Y that liquid Without the gas type, ZBSF-1 ZBSG-2, respectively, 60 degrees and 200 degrees. Third, the main technical parameters: Working medium: corrosive gases, corrosive liquids, steam, all kinds of oil, water and so on. Medium temperature: ZBSF-1 ≤ 60 degrees ZBSF-2 ≤ 200 degrees Nominal pressure: 1.6mpa Working pressure: 0-1.6mpa Voltage: AC220V, DC24V, AC380V, etc. are free to choose Custom Nominal diameter: DN15-DN250 ( Can be customized larger diameter) Third, the troubleshooting and routine maintenance: 1. The valve must be installed horizontally, for vertical installation must be customized contact with our factory technicians (may cause the valve can not be opened or can not be closed). 2. The medium must be leftward or backwardward (may cause the valve can not be closed) 3. Ambient temperature must not exceed 50 degrees (may lead to coil burned) 4. The pipeline medium may not back pressure (may cause the valve can not be completely closed) 5. Pipeline media Temperature may not be too high (may cause the valve spool temperature is too high expansion stuck) 6. Solenoid valve coil may not be energized for a long time (leading to the coil temperature is too high to melt the coil of high temperature paint to burn the coil) 7. The pipeline medium shall not contain particles or consistency Too high (resulting in the valve closed can not reach 0 leak or can not be normally open) The above is not only the use of universal customers may not only the failure and failure analysis, if you have other problems can be accessed (

Hot Oil Popcorn Machine

Popcorn Equipment,Hot Oil Popcorn Machine,Electromagnetic Heating Popcorn Machine,Stainless Steel Popcorn Machine

Jinan RuiHan Trading Company Limited , https://www.ruihangroup.com

This entry was posted in on